Acer AR380 F1 specifications
UL/cUL
CB
Nemko/GS
Environmental Specifications
Dimensions 438.4 mm (W) x 705 mm (D) x 88.1 mm (H) ( 17.3 x 27.8 x 3.5 inches)
Weight Maximum 39 kg (88.1 lbs)
Minimum (includes a single HDD, CPU and
RAM, and PSU)
28.5 kg (62.8 lbs)
System inlet
temperature
Operating 10° - 35° C (50° - 9 F)
Non-operating -40° - 70° C (-40° - 158° F)
Relative
humidity
Operating 8 - 90 %
Non-operating 5 - 95 %
Acoustics Idle
LWAd 6.4 BA
LpAm 45.8 dBA
Operating
LWAd 7.2 BA
LpAm 53.6 dBA
Power Rated Steady –state power 720 W
Maximum Peak Power 728 W
BTU rating 2456.64 BTU/hr at 100 - 240 VAC